Epson L5190-L5198 Error 0x02C0
The Epson L5190-L5198 is a high-quality printer that is widely used in homes and offices. However, users may sometimes encounter an error code 0x02C0 on the printer display, accompanied by the message “EJ2 PID lock error.” This error indicates that the EJ2 motor did not run properly or that there are obstacles present in the paper path.
One possible cause of this error is an overload of the paper feed mechanism, which can occur when too much paper is loaded into the printer. Another potential issue is a frayed or jumping EJ2 timing belt, or a disengaged or broken tooth in the wheel train of the paper feed mechanism.
The error can also be attributed to a failure to read the EJ2 motor encoder. This may be caused by contamination of the EJ2 encoder scale or a disconnection, break, skew, or damage of the EJ2 encoder flexible flat cable (FFC). Additionally, the error may be due to a failure of the EJ2 encoder sensor or the EJ2 motor itself, caused by a broken lead wire or a disconnected connector.
In some cases, the error may be attributed to a failure of the main board, which controls the overall functioning of the printer.
To troubleshoot this error, users are advised to first check for any paper jams or obstructions in the paper path. If a jam or obstruction is found, it should be carefully removed. Additionally, users can try resetting the printer by turning it off and then on again.
If the error persists, it is recommended to contact Epson customer support for further assistance. A technician may need to inspect the printer and perform repairs or replacements if necessary, especially in cases where the error is caused by mechanical failures or issues with the main board.
Printer Model | Epson L5190-L5198 |
Error Code | 0x02C0 |
Display on | PRINTER |
Description and troubleshooting | EJ2 PID lock error. The EJ2 motor did not run or obstacles exist in the paper path. Overload of the paper feed mechanism. The EJ2 timing belt become frayed, jumping, or the wheel train of paper feed mechanism is disengaged or its tooth is broken Failed to read The EJ2 motor encoder. Contamination of The EJ2 encoder scale. Disconnection, break, skew or damage of The EJ2 encoder FFC. Failure of The EJ2 encoder sensor. Failure of The EJ2 motor (the lead wire is broken or the connector is disconnected). Failure of the main board. |