Epson PX-105 Error Code OxOA Part 43461

Epson PX-105 Error OxOA

Epson PX-105 Error OxOA

The Epson PX-105 printer is an efficient and reliable printing device commonly used in offices and homes. However, like any electronic equipment, it is prone to encountering errors that can hinder its functionality. One such error is the OXOA error code, which is displayed on the printer’s screen. This error code signifies a CR LOAD POSITION excess load error, indicating an issue with the printer’s carriage.

There are several possible causes for this error code. One possibility is a CR encoder failure, which means there is a problem with the encoder responsible for tracking the carriage position. Another potential cause is a CR motor failure, meaning the motor that controls the movement of the carriage is not functioning correctly. Additionally, carriage overload, tooth skip, or improper tension of the timing belt can also trigger this error. Lastly, a cable or FFC (Flat Flexible Cable) disconnection can result in the OXOA error code.

To troubleshoot this issue, there are a few steps you can take. First, ensure that there are no foreign objects obstructing the carriage’s movement. Clean the carriage path to eliminate any potential blockages. Check the encoder strip to ensure it is clean and free from any dust or debris. Inspect the timing belt for any signs of wear or damage, and adjust the tension if necessary. Moreover, ensure that all cables and FFC connections are secure and properly connected.

If the problem persists after performing these troubleshooting steps, it is recommended to contact Epson customer support for further assistance. Their technical team will provide you with additional guidance to resolve the OXOA error code and get your printer back up and running smoothly.

Printer Model Epson PX-105
Error Code OxOA
Display on PRINTER
Description and troubleshooting CR LOAD POSITION excess load error. CR encoder failure. CR motor failure. Carriage overload. Tooth skip or improper tension of the timing belt. Cable or FFC disconnection.