Epson PX-M884F Error Code 0x02C7 Part 48196

Epson PX-M884F Error 0x02C7

Epson PX-M884F Error 0x02C7

Epson PX-M884F is a high-quality printer that is known for its efficient performance. However, there are instances when users encounter error codes, such as the error code 0x02C7, which may display on the printer’s screen. In this particular case, the error is related to the EJ2 load position excess load error.

The EJ2 motor, responsible for the printer’s operation, has stopped running midway due to various reasons. Some common causes include obstacles like jammed paper, overload of the paper feed mechanism, or disengagement/breakage of the gears. Another possible cause could be the failure to read the EJ2 motor encoder or jumping of the timing belt. Contamination of the EJ2 encoder scale or partial failure of the EJ2 motor are also potential factors. In rare cases, the error may be associated with the failure of the main board.

To troubleshoot this error, users can try the following steps:

1. Clear any jams or obstacles from the printer, ensuring that the paper feed mechanism is not overloaded.
2. Check for any visible signs of disengagement or breakage of the gears and fix them if necessary.
3. Clean the EJ2 encoder scale, which may be contaminated and affect its functionality.
4. Restart the printer to see if the error persists.
5. If the error continues, try replacing the EJ2 motor or the main board, depending on the specific issue.

It is recommended to consult the printer’s user manual or contact Epson technical support for further assistance and to avoid any further damage to the printer.

Printer Model Epson PX-M884F
Error Code 0x02C7
Display on PRINTER
Description and troubleshooting EJ2 load position excess load error. The EJ2 motor stopped running in the middle of the operation. The EJ2 was stopped by Obstacles such as jammed paper Overload of the paper feed mechanism Disengaging or breakage of the gears. Failed to read The EJ2 motor encoder. Jumping of the timing belt. Contamination of The EJ2 encoder scale. Failure of The EJ2 motor (not completely broken). Failure of the main board.