Epson PX-S884 Error 0x008D
The Epson PX-S884 printer is equipped with an error code display that can sometimes be perplexing. One such error code is 0x008D, which usually indicates a STK PID excess load error. This means that the Stacker motor, responsible for stacking paper during printing, has stopped running abruptly during an ongoing operation. Several factors can contribute to this error, such as overload of the mechanism, broken gears, encoder error, contamination of the Stacker motor encoder scale, failure of the Stacker motor, or even failure of the main board.
To troubleshoot this error, there are a few steps you can follow. Firstly, check for any obstructions or paper jams in the Stacker area. Clearing these may help resolve the issue. Next, inspect the gears within the Stacker motor mechanism for any signs of damage or wear. If any gears are broken, they will need to be replaced. In some cases, an encoder error may be the root cause. In such instances, cleaning the Stacker motor encoder scale to remove any dirt or contamination may fix the problem.
If the error persists, it is possible that the Stacker motor has malfunctioned and needs to be replaced. Alternatively, the failure of the main board could be causing the issue. In such situations, it is recommended to contact Epson customer support or a qualified technician for further assistance. They will be able to provide you with specific troubleshooting steps or schedule a repair if necessary.
In conclusion, the Epson PX-S884 printer’s error code 0x008D indicates a STK PID excess load error, which could result from various issues related to the Stacker motor and its associated mechanism. By following recommended troubleshooting steps or seeking professional assistance, you can resolve this error and get your printer functioning smoothly once again.
Printer Model | Epson PX-S884 |
Error Code | 0x008D |
Display on | PRINTER |
Description and troubleshooting | STK PID excess load error. The Stacker motor stopped running in the middle of the operation. Overload of the mechanism. Broken gears. Encoder error. Contamination of the Stacker motor encoder scale. Failure of the Stacker motor. Failure of the main board. |